Si18-201
Main Functions
Main Functions
85
1.1.7
ON/OFF Button on Indoor Unit
For FTK, FTX50/
60 H Series Only
An ON/OFF switch is provided on the front panel of the unit. Use this switch when the remote
controller is missing or if its battery has run out.
Every press of the switch changes from Operation to Stop or from Stop to Operation
"
Push this button once to start operation. Push once again to stop it.
"
This button is useful when the remote controller is missing.
"
The operation mode refers to the following table.
"
In the case of multi system operation, there are times when the unit does not activate with
this button.
1.1.8
Signal Receiving Sign
When the indoor unit receives a signal from the remote controller, the unit emits a signal
receiving sound.
1.1.9
Air Purifying Filter
For FTK(X)25/35 J,
FTK(X)50/60 H
Series
The air purifying filter (electrostatic filter) catches pollen or smoke of cigarette as small as 0.01
micron through electro static charging. An activated carbon deodorizing filter in a net shape is
also mounted to absorb and minimize fine odor particles.
1.1.10
Washable Grille
Washable grille is for FTK(X)25/35 J, FTK(X)50/60 H Series only
In the Case of FTK,
FTX50/60 H Series
Note:
Refer to P97 in Si12-001 for FTK25/35 J Series “Cleaning the air filters.”
Open the Front
Grille.
"
Hold the grille by the tabs on the two sides and lift it until it stops with a click.
Remove the Front
Grille.
"
Supporting the front grille with one hand, release the lock by sliding down the knob with the
other hand.
"
To remove the front grille, pull it toward yourself with both hands.
Mode
Temperature setting
Air flow rate
FTK
COOL
22ºC
AUTO
FTX
AUTO
25ºC
AUTO
Содержание FTX25JVEA9
Страница 9: ...Si18 201 viii Table of Contents...
Страница 71: ...Specifications Si18 201 58 Specifications...
Страница 206: ...Si18 201 Remote Controller Operations 193 1 1 2 FVX25 35KZ...
Страница 207: ...Remote Controller Si18 201 194 Operations 1 1 3 FTXD25 35KZ...
Страница 208: ...Si18 201 Remote Controller Operations 195 1 1 4 FTK FTX50 60H...
Страница 209: ...Remote Controller Si18 201 196 Operations 1 1 5 FTKD FTXD50 60 71J...
Страница 213: ...Remote Controller Si18 201 200 Operations 1 1 9 FHYC35 50 60 71K Optional Accessory BRC7C612WC...
Страница 214: ...Si18 201 Remote Controller Operations 201...
Страница 216: ...Si18 201 Remote Controller Operations 203...
Страница 217: ...Remote Controller Si18 201 204 Operations...
Страница 234: ...Si18 201 Method of Field Set Operating Test 221 2 3 Interface Adaptor for Room Airconditioner KRP928A1S...
Страница 237: ...Method of Field Set Si18 201 224 Operating Test...
Страница 262: ...Si18 201 Troubleshooting SkyAir Indoor Unit Service Diagnosis 249...
Страница 393: ...Wiring Diagrams Si18 201 380 Appendix FHYC35 50 60 71KVE9 3D005668C...
Страница 394: ...Si18 201 Wiring Diagrams Appendix 381 FHYC35 50 60 71KV1C9...
Страница 395: ...Wiring Diagrams Si18 201 382 Appendix FDYM60 03FAV1 FDYM60 03FAVAL C 3D019816D OPTION...
Страница 396: ...Si18 201 Wiring Diagrams Appendix 383 FDYM60 03FAV1C...