Si18-201
ii
Table of Contents
NOTICE : Special specifications
Model RMK140JAVM has the following different specifications from the others. Take the important notes below. This
model is designed for cooling mode only, which means it has no heating functions at all.
★
★
★
★
Important points : The model is not equipped with the receiver circuit.
1) The heating mode is not available because the following parts are not built in.
2) The following control features are not available.
3) Change the following values for this model.
4) The model is not provided with the surplus refrigerant control function.
PART 5 (5) EVL : Liquid pipe motorized valve
Page
103~105
(6) EVG : Gas pipe motorized valve
(8) Capillary tube for gas purge
(9) Check valve
(10) Check valve
PART 5 3.8
Defrost Operation
Page 122
3.12
Peak Cut Control
Page 128
3.23
Warm-Up Function
Page 141
3.27
Cooling Outdoor Unit SC Control
Page 151
3.30
SH Control in Cooling Operation
Page 157
3.31
SC Control in Heating Operation
Page 159
3.32
Heat Exchanger Isothermal Control in Heating Operation
Page 161
3.34
Inter-BP Units Heating Heat Exchanger Isothermal Control
Page 163
3.37
4-Way Valve Operation
Page 166
PART 5 3.11.1 20sec
→
10sec
Page 126
PART 6 See "1.7 Cooling operation (multi-room operation - without surplus refrigerant control function) ".
Page 178
Содержание FTX25JVEA9
Страница 9: ...Si18 201 viii Table of Contents...
Страница 71: ...Specifications Si18 201 58 Specifications...
Страница 206: ...Si18 201 Remote Controller Operations 193 1 1 2 FVX25 35KZ...
Страница 207: ...Remote Controller Si18 201 194 Operations 1 1 3 FTXD25 35KZ...
Страница 208: ...Si18 201 Remote Controller Operations 195 1 1 4 FTK FTX50 60H...
Страница 209: ...Remote Controller Si18 201 196 Operations 1 1 5 FTKD FTXD50 60 71J...
Страница 213: ...Remote Controller Si18 201 200 Operations 1 1 9 FHYC35 50 60 71K Optional Accessory BRC7C612WC...
Страница 214: ...Si18 201 Remote Controller Operations 201...
Страница 216: ...Si18 201 Remote Controller Operations 203...
Страница 217: ...Remote Controller Si18 201 204 Operations...
Страница 234: ...Si18 201 Method of Field Set Operating Test 221 2 3 Interface Adaptor for Room Airconditioner KRP928A1S...
Страница 237: ...Method of Field Set Si18 201 224 Operating Test...
Страница 262: ...Si18 201 Troubleshooting SkyAir Indoor Unit Service Diagnosis 249...
Страница 393: ...Wiring Diagrams Si18 201 380 Appendix FHYC35 50 60 71KVE9 3D005668C...
Страница 394: ...Si18 201 Wiring Diagrams Appendix 381 FHYC35 50 60 71KV1C9...
Страница 395: ...Wiring Diagrams Si18 201 382 Appendix FDYM60 03FAV1 FDYM60 03FAVAL C 3D019816D OPTION...
Страница 396: ...Si18 201 Wiring Diagrams Appendix 383 FDYM60 03FAV1C...