ESIE11-02
Checking the Inputs and Outputs
3–19
3
3
4
5
1
Overview fuses and
overcurrent
The table below contains an overview of the fuses and overcurrent for types EUWA*5-24KBZW1 and
EUWY*5-24KBZW1.
All models (400 V)
Fuses +
overcurrent
5HP
8HP
10HP
12HP
16HP
20HP
24HP
F4
8 A
8 A
8 A
8 A
8 A
8 A
8 A
F5
125 mAT
125 mAT
125 mAT
125 mAT
125 mAT
125 mAT
125 mAT
F7, F8
5 A
5 A
5 A
5 A
5 A
5 A
5 A
F1U
5 A
5 A
5 A
5 A
5 A
5 A
5 A
F3U
315 mAT
315 mAT
315 mAT
315 mAT
315 mAT
315 mAT
315 mAT
K4S
9 A
13 A
16 A
24 A
13 A
16 A
24 A
K5S
___
___
___
___
13 A
16 A
24 A
K6S
(st. pump)
1.4 A
1.4 A
1.4 A
1.4 A
2 A
2 A
2 A
K6S
(op. pump
high)
2 A
2 A
2 A
2 A
3.7 A
3.7 A
3.7 A
Units with integrated pump
Fuses
5HP
8HP
10HP
12HP
16HP
20HP
24HP
F1, F2, F3
(=gL/gG)
3 X 20 A
3 X 25 A
3 X 32 A
3 X 40 A
3 X 50 A
3 X 50 A
3 X 63 A
Units without integrated pump
Fuses
5HP
8HP
10HP
12HP
16HP
20HP
24HP
F1, F2, F3
(=gL/gG)
3 X 20 A
3 X 25 A
3 X 25 A
3 X 32 A
3 X 40 A
3 X 50 A
3 X 63 A
Содержание EUWY 24KBZW1 Series
Страница 2: ......
Страница 8: ...ESIE11 02 vi Table of Contents 3 1 4 5...
Страница 10: ...Introduction ESIE11 02 viii 3 1 4 5...
Страница 12: ...ESIE11 02 1 2 Part 1 System Outline 3 1 1 5...
Страница 86: ...Wiring Layout ESIE11 02 1 76 Part 1 System Outline...
Страница 88: ...ESIE11 02 2 2 Part 2 Functional Description 3 1 2 5...
Страница 128: ...The Digital Controller ESIE11 02 2 42 Part 2 Functional Description 3 1 2 4 5...
Страница 130: ...ESIE11 02 3 2 Part 3 Troubleshooting 3 1 3 5...
Страница 168: ...ESIE11 02 4 2 Part 4 Commissioning and Test Run 3 1 4 5...
Страница 198: ...Test Run and Operation Data ESIE11 02 4 32 Part 4 Commissioning and Test Run 3 1 4 5...
Страница 200: ...ESIE11 02 5 2 Part 5 Maintenance 3 1 5...
Страница 210: ...ESIE11 02 4 Index 3 1 4 5...