SiBE12-816_D
Indoor Unit
Printed Circuit Board Connector Wiring Diagram
34
1.1.2 FTXG25/35JV1BW(S), CTXG50JV1BW(S)
Connectors and
Other Parts
PCB (1): Control PCB
PCB (2): Signal Receiver / Display PCB
PCB (3): INTELLIGENT EYE Sensor PCB
1) S21
Connector for centralized control (HA)
2) S25
Connector for INTELLIGENT EYE sensor PCB
3) S32
Indoor heat exchanger thermistor
4) S41
Connector for swing motors
5) S42
Connector for reduction motor (front panel mechanism) and limit switch
6) S46
Connector for signal receiver / display PCB
7) S200
Connector for fan motor
8) H1, H2, H3,
FG
Connector for terminal board
9) JB
Fan speed setting when compressor stops for thermostat OFF
JC
Power failure recovery function (auto-restart)
∗
Refer to page 306 for detail.
10) LED A
LED for service monitor (green)
11) F1U
Fuse (3.15 A, 250 V)
12) V1
Varistor
1) S51
Connector for control PCB
2) S52
Connector for room temperature thermistor
3) S1W
Forced operation ON/OFF button
4) H1P
LED for operation (multi-color)
5) H2P
LED for INTELLIGENT EYE (green)
6) JA
Address setting jumper
∗
Refer to page 303 for detail.
1) S36
Connector for control PCB
Содержание 2MKS40G2V1B