SiBE12-816_D
Outdoor Unit
Removal Procedure
292
1.7
Removal of Four Way Valve / Electronic Expansion
Valves
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1. Remove the peripheries.
Preparation
Remove the sound blankets.
Detach the four way valve
coil and the clamp, and then
detach the wire harnesses.
1
Remove the screw and
remove the four way
valve coil.
2
Pull out the electronic
expansion valve coils.
3
Remove the putty.
4
Remove the terminal
cover.
(R7644)
(R7703)
(R7645)
(R7646)
Terminal cover
(R7637)