SiBE12-816_D
Service Check Function
Service Diagnosis
206
3.1.3 ARC433 Series Remote Controller
Check Method 1
1. When the timer cancel button is held down for 5 seconds, “
00
” indication appears on the
temperature display section.
2. Press the timer cancel button repeatedly until a long beep sounds.
The code indication changes in the sequence shown below.
<ARC433B41>
<ARC433B67, B68, B69, B76>
Note:
1. A short beep “pi” and two consecutive beeps “pi pi” indicate non-corresponding codes.
2. To return to the normal mode, hold the timer cancel button down for 5 seconds. When the
remote controller is left untouched for 60 seconds, it also returns to the normal mode.
3. Not all the error codes are displayed. When you cannot find the error code, try the check
method 2. (
→
Refer to page 207)
Timer cancel button
(R14221)
< ARC433 Series >
No.
Code
No.
Code
No.
Code
1
00
12
F6
23
A1
2
U4
13
C7
24
E1
3
L5
14
A3
25
UA
4
E6
15
H8
26
UH
5
H6
16
H9
27
P4
6
H0
17
C9
28
L3
7
A6
18
C4
29
L4
8
E7
19
C5
30
H7
9
U0
20
J3
31
U2
10
F3
21
J6
32
EA
11
A5
22
E5
33
AH
No.
Code
No.
Code
No.
Code
1
00
12
C7
23
H0
2
U4
13
H8
24
E1
3
F3
14
J3
25
P4
4
E6
15
A3
26
L3
5
L5
16
A1
27
L4
6
A6
17
C4
28
H6
7
E5
18
C5
29
H7
8
F6
19
H9
30
U2
9
C9
20
J6
31
UH
10
U0
21
UA
32
EA
11
E7
22
A5
33
AH