DKVM-IP8 User Manual
90 / 104
DKVM-IP8 has been started. If the DKVM-IP8 loses power or a hard reset
is performed, all logging data will be lost. To avoid this, use one of the
following log methods.
NFS Logging enabled
Define a NFS server, where a directory or a static link have to be exported, to write
all logging data to a file that is located there. To write logging data from more than
one DKVM-IP8 devices to only one NFS share, you have to define a file name that
is unique for each device. When you change the NFS settings and press the button
“Apply” , the NFS share will be mounted immediately. That means, the NFS share
and the NFS server must be filled with valid sources or you will get an error
message.
SMTP Logging enabled
With this option, the DKVM-IP8 is able to send Emails to an address given by the
Email address text field in the Event Log Settings. These mails contain the same
description strings as the internal log file and the mail subject is filled with the event
group of the occurred log event. In order to use this log destination you have to
specify a SMTP server, that has to be reachable from the DKVM-IP8 device and
that needs no authentication at all (<serverip>:<port>).
SNMP Logging enabled
If this is activated, the DKVM-IP8 sends a SNMP trap to a specified destination IP
address, every time a log event occurs. If the receiver requires a community string,
you can set it in the appropriate text field. Most of the event traps only contain one
descriptive string with all information about the log event. Only authentication and
host power events have an own trap class that consists of several fields with
detailed information about the occurred event. To receive this SNMP traps, any
SNMP trap listener may be used.
Here is a example of all gerenated event and its event group.
Device succesfully started
device
Board Reset performed by user...
device
Firmware upload failed.
device
No firmware file uploaded.
device
Uploaded firmware file discarded.
device
Firmware validation failed.
device
Firmware file uploaded by user...
device
Firmware updated by user...
device
Internal log file cleared by user...
device
Security Violation
security
Host Power
host
Host Reset
host
Connection to Remote Console failed: reason.
console (several)
Содержание DKVM-IP8
Страница 1: ...D Link DKVM IP8 8 Port KVM Switch Over IP V1 0 2011 2 23 ...
Страница 5: ...DKVM IP8 User Manual 5 104 D DKVM IP8 port table 102 E Bandwidth Consumption 103 F Cable diagrams 104 ...
Страница 57: ...DKVM IP8 User Manual 57 104 Figure 6 13 Nero selection dialog ...
Страница 64: ...DKVM IP8 User Manual 64 104 3 Click Connect Drive or Connect ISO 4 Select a drive to redirect if Connect Drive ...
Страница 104: ...DKVM IP8 User Manual 104 104 F Cable diagrams CAT5 5E 6 Straight Through UTP STP Cable ...