8-port Gigabit Ethernet Switch User’s Guide
194
Figure 7-63. Port Error Packet screen
Items on the screen above include:
•
Update Interval
– The interval (in seconds) that the table is updated. The default is
Suspend.
Rx Received packets
•
CRC Error
– For 10 Mbps ports, the counter records CRC errors (FCS or alignment errors). For 100 Mbps ports,
the counter records the sum of CRC errors and code errors (frames received with rxerror signal).
•
Undersize
– The total number of frames received that were less than 64 octets long (excluding framing bits, but
including FCS octets) and were otherwise well formed.
•
Oversize
– The total number of frames received that were longer than 1518 octets (excluding framing bits, but
including FCS octets) and were otherwise well formed.
•
Fragments
– The total number of frames received that were less that 64 octets in length (excluding framing
bits, but including FCS octets) and had either an FCS or an alignment error.
•
Jabbers
– The total number of frames received that were longer than 1518 octets (excluding framing bits, but
including FCS octets), and had either an FCS or an alignment error.