8-port Gigabit Ethernet Switch User’s Guide
148
1.
Starting at the main window of the User Interface, click
Configuration
and then press
Switch
IP
Setup
.
2.
Enter the IP address, the subnet mask, and the management VD in the fields offered.
3.
Click
Apply
to make the change effective. Use
Save Changes
on the
Maintenance
menu to enter
the IP address into NV-RAM.
Setting a Default Gateway
The default gateway parameter defines the IP address of a router or other network device to which IP packets are to be sent
if destined for a subnet outside of that in which the switch is operating. This parameter must be set if you are attempting
to manage the Switch from a remote network or across the Internet.
1.
Starting at the main window of the User Interface, click
Configuration
and then press
Switch
IP Setup
.
2.
Enter the router IP address and click
Apply
. Use
Save Changes
on the
Maintenance
menu to enter the IP
address into NV-RAM.
Setting the Administrator Password
Management access to the Switch is restricted based on the administrator password. Administrators have read/write
access for parameters governing the SNMP agent. You should therefore assign a password to the default administrator as
soon as possible, and store it in a safe place.
Setting Trap Destinations
If you wish to record SNMP traps, or events, generated by the Switch, you must configure a destination for the IP Trap
Managers. A trap destination is the IP address of the computer system on which the Web-based manager is being run.
1.
Starting at the main menu of the User Interface, click
Management
and then press
Trap
Receivers
.
2.
Enter the IP address and community name.
3.
Move to the Status field, and select
Enabled
.
4.
Click
Apply
to make the changes effective. Use
Save Changes
on the
Maintenance
menu to enter the
configuration into NV-RAM.
Saving Configuration Changes
Clicking the
Apply
button makes any configuration change active, but only for the current session. If the Switch is
restarted (rebooted) without entering the configuration changes into the non-volatile RAM (flash RAM), the configuration
changes will be lost.
To enter configuration changes into the Switch’s non-volatile RAM, select
Save Changes
from the
Maintenance
menu.
Click on the
Save Configuration
button to enter the current configuration into NV-RAM. The configuration will then
be loaded into the Switch’s memory when it is restarted.
Содержание DGS-3308 Series
Страница 23: ...8 port Gigabit Ethernet Switch User s Guide 13 Figure 4 2 Switch to switch connection ...
Страница 161: ...8 port Gigabit Ethernet Switch User s Guide 151 ...
Страница 162: ...8 port Gigabit Ethernet Switch User s Guide 152 Layer 2 Mode ...
Страница 163: ...8 port Gigabit Ethernet Switch User s Guide 153 ...
Страница 164: ...8 port Gigabit Ethernet Switch User s Guide 154 ...
Страница 242: ......