Mounting instructions VacuStar W900 / W1300 / W1600
Start-up
40
ATEX note
The following points must be observed when
explosive gases and gas mixtures are conveyed:
Prior to every start of the VacuStar W and during
operation:
– Check coolant
– Check oil level
– Check for leaks
Listen for abnormal noise during the suction
process. Switch off the VacuStar W if necessary.
Check the VacuStar W at regular intervals (daily)
for signs of overheating and exceptional
deformations. If necessary, switch off the
VacuStar W or do not put it into operation.
Regularly examine the VacuStar W for leaks
such as leaking oil or water or escaping gas. If
necessary, switch off VacuStar W or do not put
into operation.
If the VacuStar W is extremely hot: Switch off
VacuStar W and only switch on again after
approximately half an hour, to prevent the rotor
from starting.
7.3 Switching off
To switch off the VacuStar W, proceed as follows:
Switch off drive for the VacuStar W
Close the shut-off valves (if installed)