Mounting instructions VacuStar W900 / W1300 / W1600
Technical data
12
3.2 Technical data
VacuStar W operating data
Unit
Model
W900
Model
W1300
Model
W1600
Rated speed / speed range
[min
–1
]
1500 / 1000…1500
Nominal operating vacuum
1)
[mbar]
400
Permanent operating vacuum with cell ventilation
1)
[mbar]
100
Permanent operating vacuum without cell
ventilation
2)
[mbar]
200
Maximum final overpressure with direct drive
3), 4)
[bar]
2.0
Max. final overpressure with V-belt drive
3), 4)
[bar]
2
1.5
0.5
Sound pressure level at 7 m distance at
400 mbar / 0.5 bar excess pressure
[dB(A)]
71 / 74
75 / 79
76 / 82
Moment of inertia
[kgm
2
]
0.52
0.73
0.95
Content of oil container
[l]
7.5
7.5
7.5
Lubricating oil consumption
[l/h]
0.2
0.3
0.4
Weight (without accessories)
[kg]
220
279
339
1) Excess pressure = 0 bar
2) Securing via ventilation valve
3) Vacuum = 0 mbar
4) Securing via safety valve
Tab. 2: Operating data
VacuStar W performance data
Unit
Model
W900
Model
W1300
Model
W1600
Vacuum operation,
suction pressure: 400 mbar, speed: 1500 min
-1
1)
Suction volume flow / coupling performance
[m
3
/h] / [kW] 860 / 20.4
1220 / 28.5
1570 / 38.0
Pressure operation,
excess pressure: 0.5 bar, speed: 1500 min
-1
2)
Suction volume flow / coupling performance
[m
3
/h] / [kW] 891 / 26.0
1267 / 38.0
1572 / 47.5
1) Excess pressure = 0 bar
2) Vacuum = 0 mbar
Tab. 3: Performance characteristics