Mounting instructions VacuStar W900 / W1300 / W1600
Installation and assembly
27
6.8.6 Protection against contact
Rotating or hot parts of the system must be equipped with a
protection against contact.
Please note that the German accident prevention regulations do
not allow a maximum surface temperature of 80 °C to be
exceeded.
Observe DIN EN ISO 13857, for example, for the distances and
the layout of the protective grid.
6.8.7 Cell ventilation valve
Assembly
The VacuStar W has been prepared for operation with cell
ventilation. The connection is located above the pressure flange.
Observe the following points during installation:
1.
Install cell ventilation valve vertically.
2.
Install the fresh air lines between the VacuStar W and cell
ventilation valve.
3.
Install the control line between the connection at the suction
socket and the cell ventilation valve.
4.
Set an opening pressure of 200…300 mbar with the
VacuStar W running at the setting screw.
5.
Check the full stroke. Full stroke = 27 mm.
ATEX note
When transporting explosive gases and gas
mixtures, the control and fresh air lines must be
explosion and shock-proof (11.6 barg).
Cell ventilation valve, muffler and suction filter can be purchased
from CVS