Mounting instructions VacuStar W900 / W1300 / W1600
Installation and assembly
28
Fig. 5: Cell ventilation valve with muffler and air filter
1
Air filter (installed vertically)
2
Hose adapter
3
Muffler (installed horizontally or vertically)
4
Muffler holder
5
Connection line, max. length 1 m (not included in scope of
delivery)
6
Hose stub
7
Cell ventilation valve (installed vertically)
8
Screw connection, connection control line (recommended pipe
diameter: 10 x 1 mm)
9
Locknut
10 Adjustment nut for the adjustment and tuning of the oil
pressure
11 Spring cage
Caution: Spring is under pressure. Prior to removing the
spring cage, the springs must be completely relaxed with the
set screw.
12 Connection R1 1/2" fresh air line to VacuStar W,
max. length 300 mm
13 Shutoff valve