Mounting instructions VacuStar W900 / W1300 / W1600
Installation and assembly
22
6.6 Compensators
Compensators for the
suction and pressure lines
On the suction side, compensators with Teflon lining and vacuum
support ring should be used.
On the pressure side, you must ensure pressure resistance,
overpressures of up to 2.0 bars and temperature resistance up to
240 °C.
6.7
Suction and pressure line
Requirements
The suction and pressure lines must meet the following
requirements:
corrosion-proof
Nominal diameter according to the following table:
VacuStar
DN suction and pressure line
W900
DN 100
W1300
DN 125
W1600
DN 125
Tab. 8: Fastening screws
Installation
Install the lines as follows:
The connected lines must not have any reaction force on the
VacuStar W. Support the lines adequately.
Place suction lines rising towards the VacuStar W. The
condensate must be able to be drained.
Remove dirt, welding remainders, rust,. etc. before you put the
unit into operation.
Check the lines for leaks.
6.8 Safety equipment
The following safety equipment must be installed:
Safety valve
Ventilating valve
Monitoring the compression end temperature
Non-return valve
Vacuum suction filter
Protection against contact
Cell ventilation valve if needed
Shut-off valve in the control line
Safety pot