Mounting instructions VacuStar W900 / W1300 / W1600
Installation and assembly
25
6.8.3 Monitoring the compression end temperature
The final temperature of the VacuStar W must be monitored. A
suitable measuring instrument must be installed that switches the
VacuStar W off when the maximum permissible temperature is
reached.
Assembly
1.
Install the temperature sensor in the provided bore at the
pressure socket.
2.
Connect the temperature sensor to the superordinate vehicle
controller.
ATEX note
The temperature sensor connection must be
intrinsically unbreakable.
The maximum deactivation temperatures are:
−
for VacuStar W with cell ventilation: 195 °C
−
for VacuStar W without cell ventilation: 220 °C