Mounting instructions VacuStar W900 / W1300 / W1600
Installation and assembly
21
6.5 Installing VacuStar W
The VacuStar W is attached to the bottom of the VacuStar W with
4 attachment points.
Checking the function before the
installation
Check the rotor shaft function. Rotating the rotor shaft with your
hand must be possible.
Requirements
placed upon installation point
and attachment
The attachment points on the vehicle must feature a sufficient
load capacity and rigidness.
The attachment points must be on the same level.
The fastening screws must feature a sufficient clamping length.
Requirements
upon the installation location
The installation location must fulfil the following requirements:
protect from dirt, falling rocks and spray water.
offer sufficient space for accidental contact protection.
offer sufficient space for the connections of the suction and
pressure lines.
ensure good legibility of the instruments.
Accessible for maintenance and repair work (e.g. for replacing
the air filter, or for checking the safety and non-return valve).
Assembly
1.
Attach the VacuStar W with screws as per Tab. 7 without
tension.
2.
To keep moisture away from the VacuStar W', bags with
desiccant must be placed into the inlets and outlets. Remove
these before the VacuStar W is connected to the pipe
network.
ATTENTION!
If the bag with desiccant remains in the
VacuStar W, this may cause property damage!
Use the following screws for securing the VacuStar W:
Screw
Solidity
Torque
Screw-in depth in the
housing of the
VacuStar W
M16
8.8
190 Nm
22…24 mm
Tab. 7: Fastening screws