Mounting instructions VacuStar W900 / W1300 / W1600
Installation and assembly
31
6.9 40B40BAdditional components of the system
6.9.1 Sound absorber - oil separator
Requirement
The pressure resistance of the muffler separator must be adapted
to the permissible system pressure.
Assembly
Install the muffler oil separator between the VacuStar W and
the switch four way tap.
The oil drain must point straight down.
Connect the oil separator to a collection container via 2 or 3 oil
drains. Install 4 mm diameter diaphragms in the oil drains.
6.9.2 Collection container
Execution
The collection container must be designed as follows:
At least 10 l capacity
Ventilation cross section of 1"
Condensate and oil drain.
6.10 Safety dome
Requirement
The safety dome on the vehicle tank must be equipped with a float
valve and a baffle.
The baffle prevents the liquid from being entrained when the liquid
sloshes.