54
EXPERT 64+, rev.12
EXPERT 64+
9. CLOCK OUTPUTS
The controller has up to 12 clock outputs to
operate various devices using a real clock
timer. The user specifies the time at which
each clock output starts and stops.
A time clock starts when the
“On Time”
of a
time clock cycle is reached; the output either
stops after a certain run time or at a certain
time of day. The following diagrams show
both possibilities:
Time
Time
Output
Status
Cycle
Cycle
Output
Status
On
Start Time
(e.g. 8h30AM)
Start Time
(e.g. 8h30AM)
Time Clock:
Start/Run Mode
Time Clock:
Start/Stop Mode
Run Time
(e.g. 30m:15s)
Stop Time
(e.g. 9h00AM)
On
Off
Off
Note that the
“Start/Run”
mode allows stop-
ping the outputs with a little more precision
since it allows stopping them by the seconds
(contrarily to the
“Start/Stop”
mode which al-
lows stopping them by the minutes). Refer
to the Set-up menu in section 4.4 to choose
the desired operating mode of the time clocks
(
“Start/Stop”
or
“Start/Run”
).
1. Select
»
9. Advanced Settings
»
7. Clock*
* This menu is accessible if clock outputs are enabled
(sec. 4.4).
Clock Settings
Exit: Press Back
Change: Press Modify
Press
to select an item
(1) On Time
6:00 A
Off Time
6:00 A
(2) On Time
6:00 A
Off Time
6:00 A
[or]
(1) On Time
6:00 A
Run Time Hour
0
Minutes
0
Seconds
0
(2) On Time
6:00 A
Run Time Hour
0
Minutes
0
Seconds
0
2. Set the start & stop times or the start &
run times for each activated clock output.