14
EXPERT 64+, rev.12
EXPERT 64+
4.5. Probes
4.5.1. Activating the probe inputs
Follow these steps to enable or disable the
probe inputs.
1. Select:
»
12. Setup
»
4. Installation*
* This menu is only accessible from the installer
mode (sec. 4.2).
Optional Probes
Use Relative Humidity?
Yes
Number of Water Meters
2
Use Outdoor Temperature?
Yes
Use Static Pressure?
Yes
2. Activate the desired probes:
- Humidity probe
- Water meters (0 to 2 meters)
- Outside temperature probe
- Static pressure probe
* These settings are common to all programs of the
controller.
Use Day / Night On Time? —
Select
“Yes”
to
use different minimum ventilation parameters
at night. *
This parameter is common to all pro-
grams of the controller.
Number of Vent Door? —
Enable the proper
number of vent door outputs (0 to 2 vent
doors). *
This parameter is available if the static
pressure sensor is enabled (sec. 4.5.1).
Use attic T° probe ? —
Select
“Yes”
if a
temperature sensor is present in the attic.
*
This parameter is accessible if 2 vent doors are
enabled above.
Use Tunnel Curtain? —
Select
“Yes”
to enable
the tunnel curtain output.
Curtain Control —
Select whether the curtain
is controlled by the static pressure (SP) or by
the average house temperature. *
This parameter
is available if the tunnel curtain is activated above. In
addition, the static pressure control can only be used if
the static pressure sensor is activated (sec. 4.5.1).
# of Relays —
Select the number of relays
required (32, 40, 48, 56 or 64 relays. *
This
parameter is common to all programs of the con-
troller.
Monitor the Breaker Temperature? —
Select
“Yes”
to monitor the temperature of the main
breaker. When this function is enabled, the
controller sounds an alarm if the breaker’s
temperature gets too high.
Shown on Digit Display —
This is the in-
formation that is displayed on the red LED
display on the control panel. Choose the
information to be displayed: average house
temperature (T°), static pressure level (SP)
or an alternating display between the average
temperature and the static pressure level (T°/
SP). *
The static pressure level can only be displayed
if the static pressure sensor is activated (sec. 4.5.1).
This parameter is common to all programs of the
controller.
Содержание EXPERT 64 Plus
Страница 1: ...EXPERT 64 Temperature Controller User s manual...
Страница 62: ......