26
EXPERT 64+, rev.12
EXPERT 64+
• STATIC PRESSURE (SP) ALARMS:
*These
parameters are accessible if the static pressure is
enabled (sec. 4.5.1).
Low SP Alarm limit —
This parameter ranges
from 0.01”WC below the Hi SP limit to
0.00”WC.
High SP Alarm Limit —
This parameter
ranges from 0.01”WC above the Lo SP limit
to 0.40”WC.
Low SP Alarm Limit in Tunnel Ventilation —
This parameter ranges from 0.01”WC below
the Hi SP limit to 0.00”WC. High SP Alarm
Limit in Tunnel Ventilation — This parameter
ranges from 0.01”WC above the Lo SP limit
to 0.40”WC.
Delay —
The SP alarm is set off if the alarm
condition is maintained during this delay. It
ranges from 0 to 15 minutes in increments
of 15 seconds.
4.8.4. Critical Temperature Ramp
Ramp steps can only be modified while
the ramp function is disabled.
The critical temperature ramp func-
tion is common to all programs of the
controller.
1. Select:
»
9. Advanced Settings
»
9. Critical Alarm Ramping*
* This menu is accessible if an outside temperature
sensor is enabled.
Critical Alarm Ramping
Critical Temp.
102.0°F
day 0
103.0°F
day 25
85.0°F
day 55
78.0°F
Ramping Status: Off
2. Set the following parameters:
(Refer to the previous section to get further
information on these parameters)
Day Number —
Set the day number for each
step. This day refers to the animal age and
can be adjusted from -5 to 450 days. Nega-
tive values are used to prepare the house
before the arrival of the animals.
Critical High Temperature —
Set the critical
alarm temperature associated with each step.
Ramping Status —
Select
“Yes”
to activate
the critical alarm ramp. Once it is enabled,
the critical alarm limit becomes automatically
adjusted between consecutive steps of the
ramp. For this reason the critical alarm limit
and ramping steps cannot be modified manu-
ally while the ramp is enabled.