4.8.3. Setting the Alarm Limits
1. Select:
»
9. Advanced Settings
»
8. Alarms
2. Set the following parameters:
Exit: Press Back
Change: Press Modify
Press
to select an item
Alarm Settings
Temperature Alarms
Empty Zone
32.0 °F
Low Alarm
60.0 °F
High Alarm
90.0 °F
High Tunnel Alarm
95.0 °F
High Breaker Alarm 100.0 °F
Critical Alarm
103.0 °F
Water Spill Limit
Start Flock Meter 1
5 gal
Start Flock Meter 2
5 gal
End Flock Meter 1
25 gal
End Flock Meter 2
25 gal
End Flock Age
35 days
Static Pressure Alarms
Low Alarm
.00 “WC
High Alarm
.10 “WC
Low Tunnel Alarm
.05 “WC
High Tunnel Alarm
.15 “WC
Empty zone —
Temperature below which an
alarm sets off in an empty zone. Adjustable
from -40°F to 120°F (-40°C to 148.9°C).
Low Temperature Alarm —
House tempera-
ture below which an alarm sets off. Adjust-
able from 0.5 to 20°F (0.3 to 11.1°C) below
the house set point temperature.
High Temperature Alarm —
House tem-
perature over which an alarm sets off while
tunnel ventilation is disabled. Adjustable
from 0.5 to 20°F (0.3 to 11.1°C) above the
house set point.
High Temperature Alarm in Tunnel Ventila-
tion —
House temperature over which an
alarm sets off while the tunnel ventilation is
enabled. Adjustable from 0.5 to 20°F (0.3 to
11.1°C) above the house set point.
High Breaker Alarm* —
If the temperature of
the main breaker is monitored by a probe, set
the probe temperature over which a breaker
temperature alarm must be set off. *
Acces-
sible if the breaker’s monitoring function is enabled
in section 4.4.
Critical Temperature Alarm* —
Absolute
maximum house temperature over which
the critical temperature alarm is set off.
Adjustable from 0.5 above the house set
point to 120ºF (48.9°C). Note that this alarm
limit cannot be modified if the critical alarm
ramp function is active. Refer to the follow-
ing section to disable the ramp function (if
necessary). *
This parameter is available if an
outside temperature sensor is enabled.
• WATER METER ALARMS:
Water Spill Limit - Start Flock Meter 1-2 —
Maximum allowable water consumption per
15 minutes at the beginning of the flock. Set
this parameter separately for each water me-
ter. Adjustable from 0 to 10,000 gallons or
liters / 15 minutes. *
This parameter is accessible
if a water meter is enabled (sec. 4.5.1).
Water Spill Limit - End Flock Meter 1-2 —
Maximum allowable water consumption per
15 minutes at the end of the flock. Set this
parameter separately for each water meter.
Adjustable from 0 to 10,000 gallons or liters
/ 15 minutes. *
This parameter is accessible if a
water meter is enabled (sec. 4.5.1).
End Flock Age —
Day at which the flock ends.
The water spill limit for that day is maintained
until the beginning of a new flock (see previ-
ous graphic). This parameter is common to
both water meters. *
This parameter is accessible
if a water meter is enabled (sec. 4.5.1).