Aerial work platform
B-LIFT 18 HV
13
COD. UM0287_GB | REV. 00 | ED: 09/18
Chapter 12
GB
TROUBLESHOOTING
Error
Description
Solution
115
L1 extension length sensor,
open circuit
Check the power and L1 outputs; check for values
under the minimum
116
Extension length sensor 1, V
battery
“Check the power and L1 outputs; check for readings
over the maximum”
117
Jib sensor error at the input of
sensor card 1
Recalibrate the jib or replace the A1 jib angle sensor
118
“Jib angle sensor at the input to
sensor card 1, open circuit”
“Check the power and outputs; check for values
under the minimum”
119
Jib angle sensor at the input to
sensor card 1, V battery
Check the power and outputs; check for readings
over the maximum
121
Check W2 load cell
Saved data incorrect, recalibrate
122
W2 load cell, open circuit
Check the power and W2 outputs; check for readings
under the minimum (basket resting)
123
W2 load cell, V battery
Check the power and W2 outputs
124
Check L2 extension length
sensor
Saved data incorrect, recalibrate
125
L2 extension length sensor,
open circuit
“Check the power and L2 outputs; check for values
under the minimum”
126
Extension L2 length sensor, V
battery
Check the power and L2 outputs; check for values
over the maximum
127
Jib sensor error at the input of
sensor card 2
Recalibrate the jib or replace the jib angle sensor
128
Jib angle sensor at the input to
sensor card 2, open circuit
Check the power and outputs; check for values
under the minimum
129
Jib angle sensor at the input to
sensor card 1, V battery
Check the power and outputs; check for readings
over the maximum
131
Jib sensor error at sensor card 1
Check the sensor wiring and recalibrate the jib
132
Lev rot basket gyroscope, no
can-bus
Check the Can-Bus line
133
Auxiliary turret 1, no can-bus (
Check the Can-Bus line