![CTE B-LIFT 18 HV Скачать руководство пользователя страница 118](http://html1.mh-extra.com/html/cte/b-lift-18-hv/b-lift-18-hv_instructions-for-use-and-maintenance-manual_2693671118.webp)
10
Aerial work platform
B-LIFT 18 HV
COD. UM0287_GB | REV. 00 | ED: 09/18
GB
Chapter 12
TROUBLESHOOTING
Error
Description
Solution
58
FRONT LEFT extension
stabiliser beam sensor, open
circuit
Check the power and extension sensor outputs;
check for values under the minimum
59
FRONT LEFT L2 extension
stabiliser beam sensor, V battery
Check the power and extension sensor outputs;
check for values over the maximum
61
AT1 turret rotation sensor,
inconsistent output
“Difference between AT1 and AT2 turret > 8 degrees
for over 1 second”
62
A1 main boom angle sensor,
inconsistent output
Difference between A1 and A2 main boom > 15
degrees for over 1 second
63
A1 pantograph angle sensor,
inconsistent output
“Difference between A1 and A2 pantograph > 15
degrees for over 1 second”
64
A1 jib angle sensor, inconsistent
output
Difference between A1 and A2 jib > 15 degrees for
over 1 second
65
AT1 turret rotation sensor out of
range
Contact the CTE Assistance Centre
66
A1 main boom max angle out of
range
Contact the CTE Assistance Centre
67
A1 main boom min angle out of
range
Contact the CTE Assistance Centre
68
L1 extension length sensor
inconsistent output
Difference between L1 and L2 > 28 cm for over 1
second
69
W1 load cell inconsistent output
Difference between W1 and W2 > 20 Kg for over
1 second
71
“AT2 turret rotation sensor
inconsistent output”
“Difference between AT1 and AT2 turret > 8 degrees
for over 1 second”
72
A2 main boom angle sensor
inconsistent output
Difference between A1 and A2 main boom > 15
degrees for over 1 second
73
A4 pantograph angle sensor,
inconsistent output
Difference between A1 and A2 main boom > 15
degrees for over 1 second
74
A2 jib angle sensor, inconsistent
output
“Difference between A1 and A2 jib > 15 degrees for
over 1 second”
75
AT2 turret rotation sensor, out of
range
Contact the CTE Assistance Centre
76
A2 main boom max angle out of
range
Contact the CTE Assistance Centre