Error
Description
Solution
21
Check AT1 rot. turret angle
sensor
Saved data incorrect, recalibrate
22
AT1 rot. turret angle sensor,
open circuit
Check the power and AT1 outputs; check for
readings under the minimum
23
AT1 rot. turret angle sensor, V
battery
Check the power and AT1 outputs; check for
readings over the maximum
24
Check A1 main boom angle
sensor
Saved data incorrect, recalibrate
25
A1 main boom angle sensor,
open circuit
Check the power and A1 outputs; check for values
under the minimum
26
A1 main boom angle sensor, V
battery
Check the power and A1 outputs; check for readings
over the maximum
27
P1 pressure sensor, open circuit
“Check the power and P1 outputs; check for values
under the minimum”
28
P1 pressure sensor, V battery
Check the power and P1 outputs; check for values
over the maximum
29
S1 pressure sensor, open circuit
Check the power and S1 outputs; check for values
under the minimum
31
RIGHT REAR L1 extension
stabiliser beam sensor, V battery
Check the power and extension sensor outputs;
check for values over the maximum
32
RIGHT FRONT L1 extension
stabiliser beam sensor, open
circuit
Check the power and extension sensor outputs;
check for values under the minimum
33
RIGHT FRONT L1 extension
stabiliser beam sensor, V battery
Check the power and extension sensor outputs;
check for values over the maximum
34
Check A1 pantograph angle
sensor
Saved data incorrect, recalibrate
35
A1 pantograph angle sensor
open
“Check the power and A1 outputs; check for values
under the minimum”
36
A1 pantograph angle sensor, V
battery
Check the power and A1 outputs; check for readings
over the maximum
37
MC1 micro chain, open circuit
Check the extension chains
38
FRONT LEFT extension
stabiliser beam sensor, open
circuit
Check the power and extension sensor outputs;
check for values under the minimum