Aerial work platform
B-LIFT 18 HV
11
COD. UM0287_GB | REV. 00 | ED: 09/18
Chapter 12
GB
TROUBLESHOOTING
Error
Description
Solution
77
A2 main boom min angle out of
range
Contact the CTE Assistance Centre
78
L2 extension sensor inconsistent
output
Difference between L1 and L2 > 28 cm for over 1
second
79
W2 load cell, inconsistent output
Difference between L1 and L2 > 28 cm for over 1
second
81
Turret rotation sensor installation
Check the cables of both the sensors and the
mechanical connection to the gears
82
Turret rotation valve blocked
“Check the proper functioning of the valve”
83
Machine model
Check for the correct version of the software of the
cards
84
Extension valve blocked
“Check the proper functioning of the valve”
85
Parameters saved in the
inconsistent turret cards
Check that the software version and the machine
ile are the same on both turret cards
86
AT1 feed > 5 volts
Check the wiring
87
AT2 feed > 5 volts
Check the wiring
88
Error in the parameters of the
turret1 card
Reload the machine card and calibrate the machine
89
Error in the parameters of the
turret2 card
Reload the machine card and calibrate the machine
91
Allowable weight in the basket
exceeded
Unload the basket
92
Basket sensor card 1, no can
Check the Can-Bus line
93
Basket sensor card 2, no can
Check the Can-Bus line
94
Basket sensor card 1 error
Check the connections and the sensors and replace
card 1
95
Basket sensor card 2 error
Check the connections and the sensors and replace
card 2