Chapter 15
GB
OPTIONAL EQUIPMENT AND ACCESSORIES
Aerial work platform
B-LIFT 18 HV
5
COD. UM0287_GB | REV. 00 | ED: 09/18
9
Stabiliser retraction button;
•
press to retract all stabilisers
Procedure (Fig. 15.3):
•
stand in front of the ‘stabilisation command panel’ in the basket;
•
press the STAB button (Fig. 15.3, 2) to start the vehicle’s motor;
CAUTION
Keep the STAB button (Fig. 15.3, 2) pressed for the entire time the elevating
platform is being stabilised.
Releasing this button will immediately stop the vehicle's motor, blocking any
other operation on the control panel.
Release the button only once stabilised (OK LED, Fig 15.3, 1, lit up).
•
Extend the stabiliser beams by operating the buttons in turn (Fig. 15.3, 3, 4, 5 & 6). The same
buttons (Fig. 15.3, 3, 4, 5 and 6) also control the retraction of the beams if pressed along with
the central button (Fig. 15.3, 7).
•
Extend all stabiliser beams by pressing the button (Fig. 15.3, 8) so as to lift the vehicle and take
the weight off the suspension;
•
The platform is levelled automatically through automatic stabilisation;
•
Check that the indicator light is on (Fig. 15.3, 1), indicating the proper stabilisation of the vehicle.
CAUTION
When the indicator light comes on it does not mean that the vehicle has been
properly stabilised. This is only indicated by the spirit level (Fig. 6.3, 7).
Before getting onto the platform, make sure that the machine is properly
stabilised: chassis lifted and level, weight taken off the suspensions and all four
stabilisers resting on suitably irm ground.
If the ground is not irm enough to withstand the weight, use planks that are
suitable for the purpose and that have been checked before use.