Aerial work platform
B-LIFT 18 HV
9
COD. UM0287_GB | REV. 00 | ED: 09/18
Chapter 12
GB
TROUBLESHOOTING
Error
Description
Solution
39
FRONT LEFT extension
stabiliser beam sensor, V battery
Check the power and extension sensor outputs;
check for values over the maximum
41
Check AT2 turret rotation sensor
Saved data incorrect, recalibrate
42
AT2 turret rotation sensor, open
circuit
“Check the power and AT2 outputs; check for values
under the minimum”
43
AT2 turret rotation sensor, V
battery
Check the power and AT2 outputs; check for values
over the maximum
44
“Check A2 main boom angle
sensor”
Saved data incorrect, recalibrate
45
A2 main boom angle sensor,
open circuit
Check the power and A2 outputs; check for values
under the minimum
46
A2 main boom angle sensor, V
battery
Check the power and A2 outputs; check for values
over the maximum
47
P2 main boom pressure sensor
open
“Check the power and P2 outputs; check for values
under the minimum”
48
P2 main boom pressure sensor,
V battery
Check the power and P2 outputs; check for values
over the maximum
49
S2 main boom pressure sensor
open
“Check the power and S2 outputs; check for values
under the minimum”
51
RIGHT REAR L2 extension
stabiliser beam sensor, V battery
Check the power and extension sensor outputs;
check for values over the maximum
52
“RIGHT FRONT L2 extension
stabiliser beam sensor, open
circuit”
“Check the power and extension sensor outputs;
check for values under the minimum”
53
RIGHT FRONT L2 extension
stabiliser beam sensor, V battery
Check the power and extension sensor outputs;
check for values over the maximum
54
Check A2 pantograph angle
sensor
Saved data incorrect, recalibrate
55
A2 pantograph angle sensor
open
Check the power and A2 outputs; check for values
under the minimum
56
A2 pantograph angle sensor, V
battery
“Check the power and A2 outputs; check for values
over the maximum”
57
MC2 micro chain, open circuit
Check the extension chains