About this task
The X and Y cabinet address information, cabinet type, and coordinated cooling region (CCR) position for the
cabinet controller are stored on the cabinet controller backplane SEEP. This information must be re-entered on
the operator interface when replacing the cabinet controller backplane.
Procedure
1. Align the guide rail on the cabinet controller backplane with the guide slot in the front of the chassis.
2. Slide the backplane assembly into the chassis until it stops.
3. Make sure slot 15 is empty.
4. Working from the rear of the cabinet, replace the IP15 Torx+ screws (7) that attach the cabinet controller
backplane to the cabinet backplane.
5. Reconnect the environmental distribution board and operator interface cables to the backplane assembly.
Figure 50. Cabinet Controller Cables
6. Reinstall the cabinet controller.
System Cabinet Procedures
57