HomeVision® Pro
© Corroventa Avfuktning AB
2021.02
42 (44)
124
Alarm 3 humidity
1
Normally 1. 0 when the alarm occurs
–
shown
on the panel.
125
ContFan
1
During continuous fan operation 1 otherwise 0
126
FIX/MGI
0
0 for Fixed regulation. 1 for Mould Growth
Index.
127
Months to service
13
Number of months to service. Starts at 13
and counts down.
128
Time changed
2011‐05‐03 15:33
Logged when time is changed.
130
CU ID
725
Logging of Control Unit's ID.
132
Pairing attempt std/serv
0
Logged when the system attempts to connect a
new unit. 0 for Standard, 1 for Service.
133
Alarm Connection lost
1
Normally 1. 0 when the alarm occurs
–
shown
on the panel.
134
Alarm USB writing error
1
Normally 1. 0 when the alarm occurs
–
shown
on the panel.
135
Alarm 4 CU failure
1
Normally 1. 0 when the alarm occurs
–
shown
on the panel.
142
Corrective action taken
1
Logged when an alarm or
service message is acknowledged.
143
Lite/Pro
1
Logging of control panel version.
0 for Lite. 1 for Pro.
150
Active hrs this month
19
Logging of month's operating hours.
Occurs the last day of each month.
165
Mean temp this month
14
Logging of month's average temperature.
Occurs the last day of each month.
180
RH this month
45
Logging of the month's relative humidity
(RH). Occurs the last day of each month.
192
Active hrs/day
2.7
Number of operating hours for the day
193
Mean temp/day
14
The day's average temperature
194
Mean RH/day
43
The day's average relative humidity (RF)
Maintenance and service
HomeVision® does not need any regular servicing or maintenance.
The control panel's ability to run on battery power is only intended for use during installation work
and any service work in crawl spaces.
When this has been completed, HomeVision® must be powered by battery eliminator and it is
recommended to remove the batteries because many types and brands have a tendency to leak as
they age. This can, in turn, damage the electronics in HomeVision®.
If for any reason batteries must be replaced, use 1.5V AAA cells. Two batteries are needed.