HomeVision® Pro
© Corroventa Avfuktning AB
2021.02
34 (44)
Reconfigure unit (by regulation parameters), Crawl space
In the status view, normal view, first press
<Setup>
and then <
▼
> twice to get to the Settings
view.
In the settings view, press
<Select>
and then <
▼
>
so that the ”Reconfigure unit” row is marked.
Press
<OK>
to select this function.
The panel now asks the user to select the unit to
be reconfigured. If required, press <
▼
> to scroll to
the relevant unit. If the relevant unit is already
marked, press
<OK>
to continue.
Continuous ventilation
–
Controls fan operation. If
continuous ventilation is activated, the fan runs
continuously. If the function is not activated, the
fan only runs during dehumidification.
RH control mode
- can either be Fixed or MGI.
Fixed control is the most traditional with a set
setpoint in %RH for humidity. MGI, (Mould Growth
Index) means that the maximum permitted
humidity is temperature-dependent and that the
system is controlled by a defined safety margin. An
explanation of MGI can be found at the beginning
of this manual.
To change parameters
, press
<Change>
and scroll
using <
▼
> so that the desired row and parameter
is marked. Press
<OK>
and then use the arrow
keys to get to the desired selection, for example
Yes or No for ventilation. Confirm the selection
with
<Save>
.
From the first screen, <
▼
> leads to the next
screen, which, depending on selected control
mode, presents the actual parameters for Fixed or
MGI regulation. To change parameters, perform
the same procedure as for the previous screen.
Note that when the user selects to change a
parameter, a warning text always appears to
prevent unintentional changes.
When the change has been made and saved, if
everything is successful, a confirmation appears to
store the changes in the Control unit. If the
confirmation does not appear, repeat the
procedure.