HomeVision® Pro
© Corroventa Avfuktning AB
2021.02
33 (44)
See configuration overv
iew for all units, VentoVind™
In the status view, normal view, first press
<Setup>
and
then <
▼
> twice to get to the Settings view.
In the Settings view, press
<Select>
to mark the first line,
”See configuration overview”. Press
<OK>
to select this
function.
The aim of this function is to allow the user to see an
overview of the different units' settings in order to check
easily that they are all identically set, or that there are
intentional differences, or what the purpose of the given
installation is.
If more than three units are installed in the system, the
right-hand button has the marking <
▼
> and allows the
user to scroll down the list of units.
These screens show:
Start/Stop
–
the ratio at which the VentoVind™ fan must
start respectively stop. Alarm
–
MGP level and duration
in days to trigger an alarm about incorrect climate.
Fan
–
Present fan selection. Can be EC, AC or CR where
the latter, CR, means that the fan is controlled via relay
and thus is not speed controlled.
Delay
–
delay of fan start towards motor damper. When
the system is activated, the first damper is permitted to
open before the fan starts in order to prevent noise.
Min T
–
minimum temperature at which the system
operates, a limit to prevent cooling the space too much.
Par
–
Parallel operation, regards whether a backup
dehumidifier (if installed), is to operate in parallel with
the VentoVind™ fan or not. Usually, this must be set to
No, which means that if the dehumidifier cuts in, the
VentoVind™ fan stops.
Tacho
–
(Can only be used with EC fan) Shows whether
the fan that is used has a tachometer signal connected
to the
VentoVind™ control unit in order for the system
to know to give an alarm if the fan seems to have failed.
The last framed screens to the right only appear if a
backup dehumidifier is connected. (Backup dehumidifier
only supplied as an option when ordering)