HomeVision® Pro
© Corroventa Avfuktning AB
2021.02
12 (44)
1.
3.
Installation of control unit and connection of control panel for VentoVind™
When the control unit is to be installed, also prepare the control panel by inserting its batteries and
take it with you to the attic. Comprehensive installation instructions can be found in the enclosed
installation manual for VentoVind™. The following instructions are a brief summary.
1.
Install the supplied brackets on the control unit. Tap in the pins to secure the mountings to the
control box. Then mount the control unit on a flat surface centrally and make sure it is easy to
access.
Install the fan and all mounting hardware. Mount the indoor sensor so that it is
representative of the ambient climate by ensuring that:
•
The sensor is positioned at approximately half the height of the attic space.
•
The sensor is not directly affected by the fan's incoming air.
•
The sensor is not affected by radiation from heat sources.
•
The senor is not affected by radiation from surfaces colder than the ambient air.
Install the outdoor sensor in a location outdoors that is protected from direct sunlight and rain,
preferably under the roof overhang on the north or west gable end or under the eaves on the
house's north or west side. Sensor and cable output must be pointing down.
2.
Sealed
design
Outdoor
sensor
Control
Unit
Supply fan
Indoor sensor
Damper