HomeVision® Pro
© Corroventa Avfuktning AB
2021.02
19 (44)
Status view VentoVind™
In the status view for VentoVind™ the actual ratio between the moisture content in the attic
space and the moisture in the outdoor air is presented in the upper left corner. When the ratio is
less than one, the air in the attic is dryer than the outdoor air and vice versa. It is this ratio that is
used to control the ventilation.
The actual temperature of the attic is shown in the upper right-hand corner. The indications in
the lower part of the display show:
•
Fan symbol. When the symbol is moving, the fan is running and the attic is ventilated.
•
MGP gauge. Shows the actual Mould Growth Potential, a value that should
be below one (1.0).
•
Signal quality, a measurement of how good radio contact is between the
control panel and Control unit in the crawl space. The more bars that are
filled the better the reception. If reception disappears the bars begin to
flash.
Note that the signal quality is a measurement of how many data packages
are sent during the first transmission. The level normally increases over time
and can then vary slightly. A system that is paired as standard reconnects
automatically after a power cut. If the Control unit is restarted it takes about
three minutes before contact is re-established.
If several control units are connected to the control panel
the presentation scrolls
around between them at five second intervals. Unit description V1 indicates that the
status view from VentoVind™ V1 is currently being presented.
Ratio, indoor
and outdoor humidity
Fan symbol
MGP gauge
Attic Temperature
Radio
communication
quality
Unit name