2.
Power the control unit and fan by connecting the power cable.
Continue to point 3. for connecting to the control panel
3.
Provided that the de
humidifier or VentoVind™ installation has been completed, power the
dehumidifier or VentoVind™ control unit by connecting the power cable and getting the control
panel and then continuing according to the instructions below
NOTE! The control unit is now only open to pairing for two minutes after start.
To start the control panel in battery mode for the first time, remove the plastic strip at the
batteries. After completing the installation, the control panel must always be operated with the
enclosed battery eliminator.
If a control unit was not connected to the control
panel previously, the panel display looks like the
image to the right.
Press
OK
to continue.
For normal pairing, select Standard, which is
marked.
Press
OK
to continue.
Note: Service pairing is only temporary and
intended for service technicians.
The user is now reminded that the
Control Unit
open to pairing for two minutes after start.
If
necessary, restart the Control unit and push
Continue
.
Note: If the user selects Service pairing, a warning
appears stating that this pairing is only for service
technicians. If Service is selected by mistake, push
Escape
to cancel the process and restart.
The control panel now identifies units that are
available for pairing. Wait until it is ready, which
normally takes 30
–
40 seconds. If it takes longer,
restart the Control unit and try again.
When the search is complete, the found unit(s)
is/are then presented. If more than one unit
has been identified, select the correct unit by
checking the ID number on the reverse or short
side of the Control unit. Select the unit to
connect and push
OK
.