HomeVision® Pro
© Corroventa Avfuktning AB
2021.02
40 (44)
Ven
to
Vi
n
d
™
The alarm is triggered if the fan stops or rotates too
slowly. This alarm only appears when the system is set to
monitor the operation of an EC fan via tachometer
signal, and is only possible to use together with EC fan.
Check the set threshold value for the tacho alarm and
fan function.
This alarm means that the set MGP level has been exceeded
over a continuous period. Standard setting for this alarm is
MGP 1.0 and 5 days.
This alarm means that the system no longer has contact
with one or more indoor sensors. Use Diagnostics, See the
Sensor values function in the menu to see the applicable
sensors. Contact your retailer.
This alarm means that the system no longer has contact
with one or more outdoor sensors. Use Diagnostics, See the
Sensor values function in the menu to see the applicable
sensors. Contact your retailer.
This alarm means that the system no longer has contact
with one or more indoor or outdoor sensors. Use
Diagnostics, See the Sensor values function in the menu to
see the applicable sensors. Contact your retailer.
This alarm means that the connected backup dehumidifier is
no longer in contact with the VentoVind system. As an initial
measure, check whether the dehumidifier is still live, that its
cable has not been unplugged or that a fuse has tripped. If
problems persist, contact your dealer.
COM
M
ON
The system gives a service reminder, which occurs once a
year. Refer to the dehumidifier's manual for instructions.
When confirming via
<OK>
the counter resets and the
reminder does not appear for another year. A log entry is
created in the system.
This panel appears when there is a problem with the log.
The problem may be due to a full or malfunctioning USB
stick. Try with another FAT32 formatted USB stick. If that
does not help, contact your retailer.
For all these presentations except the warning for failed log
function, the
<Next>
button leads to a confirmation to
actions taken pictured to the right below. When
<OK>
is
pressed a log entry is created in the system so that the time
is saved and can be used as support for service technicians
for any later troubleshooting.