HomeVision® Pro
© Corroventa Avfuktning AB
2021.02
32 (44)
See overview of settings for all units, Crawl space
In the status view, normal view, first press
<Setup>
and then <
▼
>
twice to get to the Settings
view.
In the Settings view, press
<Select>
to mark the
first line, ”See configuration overview”. Press
<OK>
to select this function.
The aim of this function is to allow the user to see
an overview of the different units' settings in order
to check easily that they are all identically set, or
that there are intentional differences, or what the
purpose of the given installation is.
If more than three units are installed in the
system, the right-hand button has the marking
<
▼
> and allows the user to scroll down the list of
units.
For crawl space dehumidifiers, the units' selected
regulation principles, Fixed or MGI with their
respective setpoint values and safety margins,
followed by respective upper and lower hysteresis
are presented in the first of the images.
The second of the images, reached via the
<Next>
button, presents the set alarm level and whether
continuous fan is activated or not.