Backup Dehumidifier
- Controls whether the
system must use a backup dehumidifier.
Parallel operation
controls whether the backup
dehumidifier is to work in parallel with the
VentoVind™ fan or
not. Normally, Parallel
operation must be set to No, which means that if
the Backup dehumidifier starts the fan stops,
usually the best and most energy efficient
solution.
Modbus baud rate
–
For regulating the Baud rate
speed via RS485. VentoVind™ is set
to Baud rate
19200 at delivery.
Speed options: 1200, 2400, 4800, 9600, 14400,
19200, 38400, 56000, 57600, 115200.
Only used when connecting to central monitoring
and control system (Building Automation) RS485.
For backup dehumidifier settings see chapter:
Reconfigure unit (by regulation parameters), Crawl
space
NOTE!
When the user selects to change a parameter, a
warning text always appears to prevent
unintentional changes.
When the change has been made and saved, if
everything is successful, a confirmation appears to
store the changes in the Control unit. If the
confirmation does not appear, repeat the
procedure.
If in doubt whether the change was saved or not,
use th
e function ”See configuration overview” to
check which settings are now applicable to the
unit.