4. Programming
54
496792
select option 1 (engineer) then you must enter the engineer access code at a
keypad to reset the system after a system tamper alarm.
Level A Exit Mode (Command 39)
Use this Command to select the exit mode for Level A (full set):
Option 0
Timed. Use this option EITHER if the user completes setting the
system by pushing an exit terminate button connected to a keypad
OR if no exit terminate button is connected, and the system sets
after a delay selected using Command 44.
Option 1
Terminate. Use this option if the user completes setting the
system by pushing an exit terminate button connected to a key-
pad. Note that the exit time is infinite in this option.
Option 2
Final door set. Use this option to complete setting the system by
closing a door fitted with a Final Exit zone detector. Note that the
exit time is infinite in this option.
Option 3
Lock Set. To use this method you must install a lock switch with
the contacts connected to the ET terminals of a keypad. This
facility is available on keypad software version 1.4.2 onwards.
Note: Do not connect more than one lockswitch (or any other
device) to the keypad ET terminals. In a single system, do not
attempt to fit two lockswitches.
To set the system the user first enters their access code at a
keypad or operates a keyswitch. The control unit starts the exit
tone. Note that the exit time is infinite in this option. The user then
operates the final exit zone and turns the key in the lock switch to
“locked”. The system sets seven seconds after the lock switch
contacts open.
To unset the system the user turns the lock switch to “unlocked”
(closing the lock switch contacts). The keypads start a continuous
tone. At this point the user can lock the lockswitch again without
causing any alarm. When the user opens the final exit zone the
control unit starts the entry timer. The user completes entry by
unsetting the system in the normal way. Note that when the user
unlocks the lockswitch the control unit disables Alarm Confirma-
tion. The control unit enables Alarm Confirmation again if the user
locks the lockswitch without starting the entry timer.
If an intruder opens the final exit door without first unlocking the
lockswitch then the control unit immediately starts an unconfirmed
alarm. If the intruder goes on to violate another zone and you
have enabled Alarm Confirmation then the control unit sends a
confirmed alarm.
Содержание 9752
Страница 1: ...HARDWIRED CONTROL PANELS INSTALLATION AND PROGRAMMING GUIDE...
Страница 6: ...iv 496792 Contents...
Страница 12: ...6 496792 1 Introduction...
Страница 18: ...12 496792 2 Technical Description...
Страница 38: ...32 496792 3 Installation...
Страница 90: ...84 496792 5 Testing...
Страница 95: ...Notes...