4. Programming
34
496792
To change:
Key-in:
Notes
Default
Country Selection
0
Y
nn
Y
nn = country, one of:
0 = UK
(
Y
)
5 = France
X
1 = Ireland
X
6 = Denmark
1 = Italy
6 = Belgium
X
2 = OEM 1
X
7 = Sweden
2 = Spain
7 = Germany
X
3 = OEM 2
3 = Portugal
8 = Switzerland
X
4 = OEM 3
4 = Netherlands
9 = Austria
X
5 = Norway
Note: If you carry out this Command then the system will load all defaults for the
selected country. To change language displayed on keypad see Command 126.
Zone nn
nn
YY
ab
nn = zone number 01 to 24 (32 on 9752)
Note: for zones 1 to 9
a = Zone type, one of:
key in “01” to “09”.
00 = NU (not used)
Z01 =FEbc
For zones 17 to 24(32)
01 = PA (panic alarm)
Z02=ERbc
key in “
X
17” to “
X
24(
X
32)”
02 = FR (fire zone)
Z03-Z07=NAbc
03 = NA (normal alarm)
Z8=PA
04 = 24 (24 hour zone)
Z09-Z
X
24(
X
32)=NU
05 = FE (final exit)
06 = ER (entry route)
07 = SA (Shock Analyser)
08 = TC (Technical)
09 = KB (Keybox)
10 = SD (Smoke detector)
11 = KM (Key switch momentary)
12 = KF (Key switch latched)
13 = AM (Anti mask)
14 = FB (forbikobler zone)
b = Zone attributes, any of:
X
1 = C (chime)
X
2 = S (soak test)
X
3 = D (double knock)
X
4 = O(Omit allowed)
X
5 = b (armed in part set B)
X
6 = c (armed in part set C)
X
7 = Shock Analyser sensitivity (enter a
number in the range 1 (lowest) to 6
(maximum)
X
8 = d (armed in part set D - 9752 only)
Example: Zone 17 is a Normal Alarm, active in Part Set B, that is Omit Allowed.
Type in:
X
17
YY
Zone Number
03
Normal Alarm
X
5
Active in Part Set B
X
4
Omit Allow
Y
to store the value of the Command.
Engineer Code
20
Y
nnnn
Y
nnnn = New engineer code
7890
Содержание 9752
Страница 1: ...HARDWIRED CONTROL PANELS INSTALLATION AND PROGRAMMING GUIDE...
Страница 6: ...iv 496792 Contents...
Страница 12: ...6 496792 1 Introduction...
Страница 18: ...12 496792 2 Technical Description...
Страница 38: ...32 496792 3 Installation...
Страница 90: ...84 496792 5 Testing...
Страница 95: ...Notes...