4. Programming
496792
37
To change:
Key-in:
Notes
Default
Set Time and Date
51
Y
..... see “Setting Time and Date”
Omit Tamper Allowed
52
Y
0
Alarm contacts only
Y
1
Alarm plus tamper contacts
Abort reset
53
Y
0
Abort System
Y
1
Abort User
BVVO Superv’n Response 54
Y
0
Disabled
(9752 only)
1
Enabled
4/6 Digit Access Codes
56
Y
0
Four digit codes
Y
(9752 only)
1
Six digit codes
Battery Load Test
57
Y
0
Disabled
Y
(9752 only)
1
Enabled
Day Tamper Indication
58
Y
0
User Reset
Y
(9752 only)
1
Installer Reset
Sounder Tamper
59
Y
0
Negative voltage tamper return
Y
1
End of line 2k2 resistor.
Level B final exit
60
Y
0
B=FE = FE (Final exit)
Y
1
B=FE = NA (Normal alarm)
Level B Entry route
61
Y
0
B=ER = ER (Entry route)
Y
1
B=ER = FE (Start entry timer)
Level B Exit Mode
62
Y
0
Timed plus Low Tone
Y
1
Instant set
2
Silent set (kpd beeps at end of setting period)
3
Lock set
4
Exit mode same as Level A
Level B Alarm response
63
Y
0
Keypad Sounder Only
1
Internal Sounder and keypad sounders
Y
2
Local (all sounders, no comms)
3
Full alarm (all sounders and comms)
Level B Entry Time
64
Y
1
10 seconds
2
20 seconds
Y
3
30 seconds
4
45 seconds
5
60 seconds
6
120 seconds
Level B Exit Time
65
Y
1
10 Seconds
2
20 seconds
Y
3
30 seconds
4
45 seconds
5
60 seconds
6
120 seconds
Содержание 9752
Страница 1: ...HARDWIRED CONTROL PANELS INSTALLATION AND PROGRAMMING GUIDE...
Страница 6: ...iv 496792 Contents...
Страница 12: ...6 496792 1 Introduction...
Страница 18: ...12 496792 2 Technical Description...
Страница 38: ...32 496792 3 Installation...
Страница 90: ...84 496792 5 Testing...
Страница 95: ...Notes...