4. Programming
50
496792
Change Engineer Code (Command 20)
To change the Engineer access code:
1.
Make sure you are in programming mode.
2.
Key in 20 and press
Y
.
The display shows:
20:Code
3.
Key in a new four digit Engineer access code.
The display shows:
20:Code ****
4.
Press
Y
.
Zone Configuration (Command 21)
This Command allows you to select the wiring type of the zone connectors on
the main PCB. The options available are:
Option 0
Closed Circuit four wire with global anti tamper.
Option 1
Fully Supervised Loop (FSL).
See Chapter 3 for wiring details.
Loudspeaker Chime (Command 22)
A user may find that the chime tone from the keypads is not loud enough. If
so, then use Command 22 option 1 to make the internal sounder also give
the chime tone. To alter the volume of the tone from the internal sounder
enter a digit in the range 1 to 9. 1 is quietest, 9 is loudest. The internal
sounder demonstrates the volume of the tone when you enter the digit.
RedCare Reset (Command 23)
Option 1 enables RedCare Reset, which is designed to operate with the plug-
by communicator, or remote PC reset.
Note: You must set System Reset to Engineer (Command 33 option 1) to ensure
RedCare Reset works correctly.
After an alarm the user keys in their access code to silence the alarm, but
cannot reset the system. The first to alarm display and Service LEDs remain
visible. The user contacts the ARC, who verifies the user's identity. The ARC
sends a signal back to the control unit. The Service LED goes dark and the
end user can now reset the system with any valid access code, providing that
there are no faults.
Use option 0 (the default) to disable the function.
Show Control Unit Account Name (Command 24)
An ARC can use Downloader to program an account name into the control
unit. While the control unit is in programming mode you can display the
account name from the keypad. To do this key in 24
Y
. Press
X
to return to
programming mode.
Содержание 9752