4. Programming
496792
33
4. Programming
Entering Programming Mode
“3. Installation - Initial Power Up” describes how to enter programming mode
for the first time in a new installation. If you wish to enter programming mode
at any other time:
1.
Make sure the system is unset.
Note: If you have selected defaults for Norway, Sweden or Denmark then you must
enter a valid user code at this point.
2.
Press 0, then key in the Engineer’s code (default 7890).
The display shows:
Installer Mode
You are now in programming mode.
While the system is in programming mode all keypads except the one you
are using will be locked, displaying “Busy”.
Programming Commands
When delivered from the factory the control unit already has default program
settings. To change the default programming you must be in programming
mode. Then:
1.
Key in the appropriate Command number and press
Y
.
The display shows the current value of the Command.
2.
Key in digits to select the value you require.
The display shows the new value.
3.
Press
Y
to store the new value of the Command.
If at any time you change your mind, repeat step 1 to 3. The table on the
following pages shows the Commands and their options. ( A “Y” next to a
Command value shows that it is the factory default.)
The factory default access codes are:
Engineer Code
7890
Access Code User 1
1234
Access Code Users 2 to 16
X
002 ....
X
016 (inactive)
Duress Code
X
017 (inactive)
Note:
1. The factory default Access Codes 02 to 16 and the Duress Code must be
changed by USER 1 to a four digit number to activate them. See “9751 User
Guide” or “9752 User Guide” for a more detailed explanation of changing user
access codes.
Содержание 9752
Страница 1: ...HARDWIRED CONTROL PANELS INSTALLATION AND PROGRAMMING GUIDE...
Страница 6: ...iv 496792 Contents...
Страница 12: ...6 496792 1 Introduction...
Страница 18: ...12 496792 2 Technical Description...
Страница 38: ...32 496792 3 Installation...
Страница 90: ...84 496792 5 Testing...
Страница 95: ...Notes...