4. Programming
496792
47
Technical (TC)
(Key in 08). Use this zone type when you want to monitor
equipment, for example a freezer, without raising a full
alarm. If a technical alarm zone is activated while the
system is set, the system makes no audible alarm.
However, when a user unsets the system the keypad
indicates a fault.If a technical alarm zone is activated
while the system is unset then the system starts a pulsed
tone from the keypad. If programmed, the control unit also
starts communication. When a user enters a valid code
the keypad stops the tone and displays the zone.
Key Box (KB)
(Key in 09). This zone type is for use in Scandinavia only.
When a zone of this type is required, the Installer con-
nects the alarm wires of the zone to a special external
key box and the tamper wires to the box enclosure switch.
When someone opens the box the control unit logs the
event and communicates it to the ARC. The control unit
also provides a Key Box output type that you can pro-
gram to trigger one of the plug by communicator output
pins, see Command 151.
Smoke Detector (SD)
(Key in 10). This zone type is for use in Scandina-
via only. Use this type for zones connected to 12V smoke
detectors. This type is active whether the system is set or
unset and the control unit will transmit a specific alarm to
the ARC if triggered. The control unit also provides a
Smoke Detector output type that you can program to
trigger one of the plug by communicator output pins, see
Command 151.
If a zone of this type causes an alarm then the user will
need to enter an access code to disarm and reset the
system.
Key Switch
There are two Key Switch zone types: Momentary and
Fixed. These two zone types are intended for use on
zones that connect to an access control keypad, elec-
tronic key or other type of hardwired device used to set or
unset the system.
When the user operates the Keyswitch while the system
is unset then the control unit starts the programmed exit
mode.
When the user operates the Keyswitch while the system
is set then the control unit unsets the system immediately.
The user cannot reset the system from a Keyswitch zone.
Содержание 9752
Страница 1: ...HARDWIRED CONTROL PANELS INSTALLATION AND PROGRAMMING GUIDE...
Страница 6: ...iv 496792 Contents...
Страница 12: ...6 496792 1 Introduction...
Страница 18: ...12 496792 2 Technical Description...
Страница 38: ...32 496792 3 Installation...
Страница 90: ...84 496792 5 Testing...
Страница 95: ...Notes...