4. Programming
496792
63
Strobe
(Key in 08) In an alarm the system operates the output.
The output remains active until the user disarms the
system.
Smoke Reset
(Key in 09) This output is designed to be connected to
low voltage smoke detector reset terminals. The control
unit operates the output for 3 seconds when the system
is reset after any alarm has occurred.
Siren Test
(Key in 10) This output becomes active when the
Installer performs a sounder test using Command 91.
Strobe Set
(Key in 11) This output is active for 10 seconds after the
system has set. The output can be used to operate the
strobe to give a visual indication that the system has
completed setting.
Pulse Set
(Key in 12) This output becomes active for 1 second
when the system is fully set, or during a fire or PA
alarm.
Pulse Unset
(Key in 13) This output becomes active for 1 second
when someone unsets the system, or during a fire or
PA alarm.
Alarm Confirm
(Key in 14) This output is active during a confirmed
alarm.
Set Complete
(Key in 15) This output is active for 10 seconds when
someone successfully sets the system.
Unset Complete
(Key in 16) This output is active for 10 seconds when
someone unsets the system, or disarms it after an alarm.
Burglar Communications Re-arm (Command 85)
This Command determines what happens to the “Burg” communications
output at the end of the bell run time.
Option 0
Latched. The output stays active until an engineer or user resets
the system.
Option 1
Rearm. The system rearms Channel 3 once the bell timer has
expired. Once the Channel is rearmed, the system is ready to
report any new alarm. The system bypasses any detectors that
are still violated.
Notes:
1. If a
Final Exit Zone
is triggered, Channel 3 becomes active at the end of the
Programmed Entry time, or,
2. If
Dual Ply Entry
is enabled (Command 86 1) and the Final Exit zone is
triggered then Channel 3 becomes active at the end of the 30 second Dual ply
grace period, or,
Содержание 9752
Страница 1: ...HARDWIRED CONTROL PANELS INSTALLATION AND PROGRAMMING GUIDE...
Страница 6: ...iv 496792 Contents...
Страница 12: ...6 496792 1 Introduction...
Страница 18: ...12 496792 2 Technical Description...
Страница 38: ...32 496792 3 Installation...
Страница 90: ...84 496792 5 Testing...
Страница 95: ...Notes...