XW-210 WiFi™ Users Manual
Max Current:
12A
Electrical Life:
100K cycles, typical @ full-rated load (higher with smaller load)
Mechanical Life:
10M cycles, typical
Environmental Rating:
Over voltage Category II, Pollution Degree 2
Control Options:
On/Off or Pulsed
Pulse Timer Duration:
100ms to 86400 Seconds (1-day)
Digital Input
Number of Inputs:
1
Minimum Pulse Time (high or low):
25mS
Input Current (Iin):
950uA @ 4V, 8.5mA @ 26V
Isolation (Viso):
1,500 Vrms
Reverse voltage (Vr):
6V max
Vin:
28V (max)
Vin Hi:
4V (min)
Vin Lo:
1.5V (max)
Input counter:
32-bit floating-point
1-Wire Sensor Input
Maximum number of sensors:
4
Works with digital “1-wire” thermometer probes
Interchangeable, no calibration needed
Dallas Semiconductor DS18B20 digital 1-wire thermometer
Available in bare or encapsulated versions
Also works with ControlByWeb™ wall-mount humidity sensors and other Xytronix 1-wire sensors.
Measurement Range:
-55°C
-
to 125°C (-67°F to 257°F)
Accuracy:
+/-0.5°C from -10°C to +85°C.
Maximum cable length:
600 feet maximum cable length
LED Indicators (4)
Green:
Power On
Yellow:
Relay On, Input On, Link
Configuration
Celsius/Fahrenheit:
User configurable
Temperature Reports:
Interval
Switch Status Reports:
Interval, on state change, or both
Report Rate:
User configurable
Email alerts
Email Alerts:
Configurable, up to 8-addresses
Encrypted Email Alerts:
Yes
Temperature Alerts:
High or low temperature
Input Status Alerts:
Input on, input off, or input change
Real-Time Clock
Manual or NTP (Network Time Protocol) setup, (not battery backed)
NTP sync configurable for once, daily, weekly or on power-up
Automatic daylight savings adjustment