Web Server
XW-210 WiFi™ Users Manual
REMOTE SERVICES
If Remote Services is enabled, the XW-210 will immediately attempt to make a connection with the
remote server (power cycle not required). Once a connection is established, the connection will remain
until it is disconnected by the remote server. If the connection is lost, it will automatically reconnect
according to the
Connection Interval
.
Hostname / IP Address:
The URL or IP address of the server you wish to send (push) data to. If the IP address is specified, enter
it in this format aaa.bbb.ccc.ddd. For numbers that are less than 100, preceding zeros should not be
included (for example, enter 80 rather than 080). This field can be up to 40 characters long and has no
default setting.
Remote Services Port:
The TCP port used for communications with the remote server. This can be set within the range of 1-
65535. The default setting for this field is 8000.
Connection String:
This text is sent to the Remote Services server when the connection is established. This string should
include any information required by the server at connection. For example, it may include an ID number,
customer number, password, etc. The format is entirely dependent upon the server requirements. This
field can be up to 80 characters long. Default text is provided only as an example placeholder. The
default text is [<
Serial Number
>]:ControlByWeb,XW-210.
Connection Interval:
This field specifies the periodic interval in which XW-210 attempts to connect to the remote server, or if
XW-210 is already connected, it is the interval in which XW-210 sends the connection string. The default
setting is 1 minute.
Version
This field specifies the version of the remote services' protocol to use. Version 1 of the protocol sends
the connection string after successfully connecting to the remote server and then periodically per the
connection interval specified. Version 2 of the protocol sends the connection string in addition to the MAC
address, connection interval, model number and then immediately sends the state.xml file of the device.
Version 2 of the protocol requires the remote server to reply to the connection string with a 3 byte packet