Operation Manual
Track Supply 6 kW
80 / 125 A at 400 / 480 V
BAL9100-0124c-EN
www.conductix.com
Page 29 of 44
10.5.6
Wiring of the Track Supply
Attention: The Track Supply is without any voltage > 60 VDC inside only when the plug or the
power supply is disconnected for longer than 10 minutes. For absolute safety please wait 20
minutes.
Observe safety precautions and make sure no others do have access to the opened Track
Supply!
To get better access to the internal components, the side lid and the front lids can be removed
For ease and quickness of access to the fuses and the Track Cable connections the specific covers in the front lid may be
removed
Example shown: connection of Track Cable through opening on the right side. Use a tightening Torque of 9-10 Nm on the stainless
steel M8 bolts. Fuses behind the left hand cover.