Operation Manual
Track Supply 6 kW
80 / 125 A at 400 / 480 V
BAL9100-0124c-EN
www.conductix.com
Page 16 of 44
7.2
Track Supply Display Board
The Track Supply display board has a backlit 3x16
character display, 3 LEDs and two push buttons for
user interaction assembled.
7.2.1
LED indication
The behavior of the three display board LEDs is as follows:
LED green
Status
Cause
Off
Track Supply not powered or
error
see red LED
Possible causes:
•
Track Supply is disconnected from the mains power
•
Problem with control board
Flashing
Track Supply in standby
mode
Normal condition due to absence of START signal on HAN-10E
On
Track Supply is running
Normal condition: START and RESET signals are present on
HAN-10E
LED red
Status
Cause
Off
Track Supply not powered or
no error
see green LED
Normal condition if there is no error.
Flashing
Track Supply in reset mode
Normal condition due to absence of RESET signal on HAN-10E
On
Track Supply error
see
yellow LED / LCD
See display for error code. Error codes are described in
section 7.2.6 below.
The yellow LED warns the user of critical operating conditions. No warning will stop operation of the Track Supply, however, a
persistent warning may subsequently lead to an error if left unattended. If more than warning is present at a time, only the most
‘Mode’ button
‘Set’ button