Operation Manual
Track Supply 6 kW
80 / 125 A at 400 / 480 V
BAL9100-0124c-EN
www.conductix.com
Page 20 of 44
Error code Description
Meaning/Cause
E004
Ground fault
•
Isolation of Track Supply or track installation damaged.
•
Water present on track
•
Ground fault level set too low.
E005
Door open
•
Pins 11 and 12 of X104 not bridged
•
Loose connection
E006
No track current
•
Track current sensor defect or wire broken
E007
Temperature high on sensor 1
•
Air intake or exhaust blocked
•
Overloading, too many loads
•
Ambient temperature too high
•
Damaged track tuning capacitors
•
Axial fan defect / Fan fuse blown
E008
Temperature high on sensor 2
See E007
E009
Temperature sensor 1 defect
•
Defect sensor
•
Loose connection
E010
Temperature sensor 2 defect
•
Defect sensor
•
Loose connection
E011
Temperature high on heat sink sensor 1
See E007
E012
Temperature high on heat sink sensor 2
See E007
E013
Heat sink temperature sensor 1 short
circuited
•
Temperature sensor wiring problem
E014
Heat sink temperature sensor 1 open
circuited
•
Temperature sensor wiring problem
E015
Heat sink temperature sensor 2 short
circuited
•
Temperature sensor wiring problem
E016
Heat sink temperature sensor 2 open
circuited
•
Temperature sensor wiring problem
E017
Temperature switch 1 open circuited
•
Loose connection
•
See E007
E018
Temperature switch 2 open circuited
•
Loose connection
•
See E007
E019
LCD
•
LCD defect
•
Loose connection between display and control boards
E020
Output (Track) voltage high
•
Track is detuned
E021
Output (Track) current high
•
Control board failure
E022
Output power high
•
Too many pickup loads on track
E023
Soft-start error
•
Soft-start circuit failure
E024
Watchdog
•
Software problem
E025
Brownout
•
Control board supply voltage failure
•
Control board on-board power supply failure