SLM-3650 Satellite Modem
Revision 3
Options
MN/SLM3650.IOM
A–33
A.1.4.5.3
Configuration #3 (Local EIA-232 to Remote EIA-485 [2-Wire])
Table A-7. Local EIA-232 to Remote EIA-485 (2-Wire)
#3. Local End Modem Settings for EIA-232
Utility: Interface Menu
ASYNC TX and RX Type
EIA-232
Configuration: Interface Menu
ASYNC TX and RX Baud Rate
150 to 38400
(See A.1.4.3.10)
ASYNC TX and RX Length
7 bits
ASYNC TX and RX Parity
Even
ASYNC TX Stop
2 bits
#3. Remote End Modem Settings for EIA-485 (2-Wire)
Utility: Interface Menu
ASYNC TX and RX Type
EIA-485 (2-wire)
Configuration: Interface Menu
ASYNC TX and RX Baud Rate
150 to 38400
(See A.1.4.3.10)
ASYNC TX and RX Length
7 bits
ASYNC TX and RX Parity
Even
ASYNC TX Stop
2 bits
Utility: System Menu
Remote Baud Rate
Equal to ASYNC TX and RX baud rate
Parity Even
Address
1 to 255
The local end cable connects the 25-pin female ASYNC connector (on either the
breakout panel or the Y cable) to the EIA-232 remote terminal (WYSE or laptop
computer). The pinout of the local cable is listed in the following table.
#3. Local End EIA-232
9-Pin
Female Connector
25-Pin
Male Connector
RX 2 3 TX
TX 3 2 RX
GND 5 7 GND
The remote end cable connects the 25-pin female ASYNC connector (on either the
breakout panel or the Y cable) to the 9-pin female connector, J6, at the rear of the
modem. The pinout of the remote cable is listed in the following table.
#3. Remote End EIA-485 (2-Wire)
9-Pin
Male Connector
25-Pin
Male Connector
TX/RX+ 4 14,
16
TX+,
RX+
TX/RX-
5
2, 3
TX-, RX-